臺灣核心實作指引(TW Core IG)
0.2.0 - Trial Use

This page is part of the 臺灣核心實作指引(TW Core IG) (v0.2.0: Releases) based on FHIR (HL7® FHIR® Standard) R4. This is the current published version in its permanent home (it will always be available at this URL). For a full list of available versions, see the Directory of published versions

Resource Profile: TWCoreObservationVitalSigns - Mappings

Active as of 2024-03-21

Mappings for the Observation-vitalSigns-twcore resource profile.

Mappings for Workflow Pattern (http://hl7.org/fhir/workflow)

TWCoreObservationVitalSigns
ObservationEvent
   identifierEvent.identifier
   basedOnEvent.basedOn
   partOfEvent.partOf
   statusEvent.status
   subjectEvent.subject
   encounterEvent.context
   effective[x]Event.occurrence[x]
   performerEvent.performer.actor

Mappings for SNOMED CT Concept Domain Binding (http://snomed.info/conceptdomain)

TWCoreObservationVitalSigns
Observation< 363787002 |Observable entity|
   status< 445584004 |Report by finality status|
   value[x]< 441742003 |Evaluation finding|
   specimen< 123038009 |Specimen|
   device< 49062001 |Device|
   component
      value[x]363714003 |Interprets| < 441742003 |Evaluation finding|

Mappings for HL7 v2 Mapping (http://hl7.org/v2)

TWCoreObservationVitalSigns
ObservationOBX
   identifierOBX.21 For OBX segments from systems without OBX-21 support a combination of ORC/OBR and OBX must be negotiated between trading partners to uniquely identify the OBX segment. Depending on how V2 has been implemented each of these may be an option: 1) OBR-3 + OBX-3 + OBX-4 or 2) OBR-3 + OBR-4 + OBX-3 + OBX-4 or 2) some other way to uniquely ID the OBR/ORC + OBX-3 + OBX-4.
   basedOnORC
   partOfVaries by domain
   statusOBX-11
   category
   category (VSCat)CE/CNE/CWE
      codingC*E.1-8, C*E.10-22
         systemC*E.3
         versionC*E.7
         codeC*E.1
         displayC*E.2 - but note this is not well followed
         userSelectedSometimes implied by being first
      textC*E.9. But note many systems use C*E.2 for this
   codeCE/CNE/CWE
      codingCE/CNE/CWE subset one of the sets of component 1-3 or 4-6
      textC*E.9. But note many systems use C*E.2 for this
   subjectPID-3
   focusOBX-3
   encounterPV1
   effective[x]OBX-14, and/or OBX-19 after v2.4 (depends on who observation made)
   issuedOBR.22 (or MSH.7), or perhaps OBX-19 (depends on who observation made)
   performerOBX.15 / (Practitioner) OBX-16, PRT-5:PRT-4='RO' / (Device) OBX-18 , PRT-10:PRT-4='EQUIP' / (Organization) OBX-23, PRT-8:PRT-4='PO'
   value[x]OBX.2, OBX.5, OBX.6
   dataAbsentReasonCE/CNE/CWE
   interpretationCE/CNE/CWE
   noteNTE.3 (partner NTE to OBX, or sometimes another (child?) OBX)
   bodySiteCE/CNE/CWE
   methodCE/CNE/CWE
   specimenSPM segment
   deviceOBX-17 / PRT -10
   referenceRangeOBX.7
      lowOBX-7
      highOBX-7
      typeCE/CNE/CWE
      appliesToCE/CNE/CWE
      textOBX-7
   hasMemberRelationships established by OBX-4 usage
   derivedFromRelationships established by OBX-4 usage
   componentcontainment by OBX-4?
      codeCE/CNE/CWE
      value[x]OBX.2, OBX.5, OBX.6
      dataAbsentReasonCE/CNE/CWE
      interpretationCE/CNE/CWE
      referenceRangeOBX.7

Mappings for RIM Mapping (http://hl7.org/v3)

TWCoreObservationVitalSigns
ObservationEntity. Role, or Act, Observation[classCode=OBS, moodCode=EVN]
   textAct.text?
   containedN/A
   identifierid
   basedOn.inboundRelationship[typeCode=COMP].source[moodCode=EVN]
   partOf.outboundRelationship[typeCode=FLFS].target
   statusstatus Amended & Final are differentiated by whether it is the subject of a ControlAct event with a type of "revise"
   category.outboundRelationship[typeCode="COMP].target[classCode="LIST", moodCode="EVN"].code
   category (VSCat)n/a, CD
      idn/a
      codingunion(., ./translation)
         idn/a
         system./codeSystem
         version./codeSystemVersion
         code./code
         displayCV.displayName
         userSelectedCD.codingRationale
      text./originalText[mediaType/code="text/plain"]/data
   coden/a, CD
      idn/a
      codingn/a, CV
      text./originalText[mediaType/code="text/plain"]/data
   subjectparticipation[typeCode=RTGT]
   focusparticipation[typeCode=SBJ]
   encounterinboundRelationship[typeCode=COMP].source[classCode=ENC, moodCode=EVN]
   effective[x]effectiveTime
   issuedparticipation[typeCode=AUT].time
   performerparticipation[typeCode=PRF]
   value[x]value
   dataAbsentReasonn/a, CD
   interpretationn/a, CD
   notesubjectOf.observationEvent[code="annotation"].value
   bodySiten/a, CD
   methodn/a, CD
   specimenparticipation[typeCode=SPC].specimen
   deviceparticipation[typeCode=DEV]
   referenceRangeoutboundRelationship[typeCode=REFV]/target[classCode=OBS, moodCode=EVN]
      idn/a
      lowvalue:IVL_PQ.low
      highvalue:IVL_PQ.high
      typen/a, CD
      appliesTon/a, CD
      ageoutboundRelationship[typeCode=PRCN].targetObservationCriterion[code="age"].value
      textvalue:ST
   hasMemberoutBoundRelationship
   derivedFrom.targetObservation
   componentoutBoundRelationship[typeCode=COMP]
      idn/a
      coden/a, CD
      value[x]value
      dataAbsentReasonn/a, CD
      interpretationn/a, CD
      referenceRangeoutboundRelationship[typeCode=REFV]/target[classCode=OBS, moodCode=EVN]

Mappings for FiveWs Pattern Mapping (http://hl7.org/fhir/fivews)

TWCoreObservationVitalSigns
Observation
   identifierFiveWs.identifier
   statusFiveWs.status
   categoryFiveWs.class
   subjectFiveWs.subject[x], FiveWs.subject
   focusFiveWs.subject[x], FiveWs.subject
   encounterFiveWs.context
   effective[x]FiveWs.done[x]
   issuedFiveWs.recorded
   performerFiveWs.actor

Mappings for SNOMED CT Attribute Binding (http://snomed.org/attributebinding)

TWCoreObservationVitalSigns
Observation
   value[x]363714003 |Interprets|
   specimen704319004 |Inherent in|
   device424226004 |Using device|
   component
      value[x]363714003 |Interprets|